TYPE measure_value

(* SCHEMA step_merged_ap_schema; *)
-- DIFF IN AP214
-- DIFF IN AP203e2
-- DIFF IN AP224
-- DIFF IN AP232
TYPE measure_value = SELECT
  (absorbed_dose_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   acceleration_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   amount_of_substance_measure,					 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   area_measure,						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   capacitance_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   celsius_temperature_measure,					 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   conductance_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   context_dependent_measure,					 -- Common
   count_measure,						 -- Common
   descriptive_measure,						 -- Common
   dose_equivalent_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   electric_charge_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   electric_current_measure,					 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   electric_potential_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   energy_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   force_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   frequency_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   illuminance_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   inductance_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   length_measure,						 -- Common
   luminous_flux_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   luminous_intensity_measure,					 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   magnetic_flux_density_measure,				 -- AP203e2/AP238 STEP-NC/AP242
   magnetic_flux_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   mass_measure,						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   non_negative_length_measure,					 -- AP203e2/AP214/AP238 STEP-NC/AP242
   numeric_measure,						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   parameter_value,						 -- Common
   plane_angle_measure,						 -- Common
   positive_length_measure,					 -- Common
   positive_plane_angle_measure,				 -- Common
   positive_ratio_measure,					 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   power_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   pressure_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   radioactivity_measure,					 -- AP203e2/AP238 STEP-NC/AP242
   ratio_measure,						 -- Common
   resistance_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   solid_angle_measure,						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   thermodynamic_temperature_measure,				 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   time_measure,						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
   velocity_measure,						 -- AP203e2/AP238 STEP-NC/AP242
   volume_measure);						 -- AP203e2/AP214/AP232/AP238 STEP-NC/AP242
END_TYPE;

Referenced By

Defintion measure_value is references by the following definitions:
DefinitionType
 measured_value_select SELECT
 measure_with_unit ENTITY
 valid_measure_value FUNCTION
 value_representation_item ENTITY


[Top Level Definitions] [Exit]

Generated by STEP Tools® EXPRESS to HTML Converter
2024-09-06T14:00:30-04:00